FED 53 Full Specification

FED 53
Exterior dimensions
Width (mm) 635
Height (incl. feet) (mm) 620
Depth (mm) 575
Plus door handle and connection (mm) 105
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 160
Exhaust duct (outer Ø mm) 52
Steam space volume (l) 77
Number of doors (ea.) 1
Interior dimensions
Width (mm) 400
Height (mm) 400
Depth (mm) 330
Interior volume (l) 53
Racks (number standard/max.) 2 / 5
Load per rack (kg) 15
Permitted total load (kg) 40
Weight (empty) (kg) 44
Temperature data
Temperature range approx. 5 °C above ambient temperature to (°C) 300
Temperature variation
at 70 °C (± K) 0,8
at 150 °C (± K) 2
at 300 °C (± K) 3,7
Temperature fluctuation at 70 °C (± K) 0,3
Warm-up time 1)
to 70 °C (min.) 6
to 150 °C (min.) 24
to 250 °C (min.) 45
to 300 °C (min.) 55
Recovery time after doors were open for 30 sec. 1)
at 70 °C (min.) 2
at 150 °C (min.) 5
at 300 °C (min.) 10
Ventilation data
Ventilation
at 150 °C (x/h) 43
at 300 °C (x/h) 66
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 230
Nominal power (kW) 1,2
at 70 °C (W) 162
at 150 °C (W) 397
at 300 °C (W) 933

 

1) To 98% of the set value

All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.