FED 400 Full Specification

FED 400
Exterior dimensions
Width (mm) 1235
Height (incl. feet) (mm) 1025
Depth (mm) 765
Plus door handle and connection (mm) 105
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 160
Exhaust duct (outer Ø mm) 52
Steam space volume (l) 498
Number of doors (ea.) 2
Interior dimensions
Width (mm) 1000
Height (mm) 800
Depth (mm) 500
Interior volume (l) 400
Racks (number standard/max.) 2 / 10
Load per rack (kg) 35
Permitted total load (kg) 90
Weight (empty) (kg) 145
Temperature data
Temperature range approx. 5 °C above ambient temperature to (°C) 300
Temperature variation
at 70 °C (± K) 1
at 150 °C (± K) 2,5
at 300 °C (± K) 4,8
Temperature fluctuation at 70 °C (± K) 0,3
Warm-up time 1)
to 70 °C (min.) 18
to 150 °C (min.) 35
to 250 °C (min.) 60
Recovery time after doors were open for 30 sec. 1)
at 70 °C (min.) 2
at 150 °C (min.) 17
at 300 °C (min.) 21
Ventilation data
Ventilation
at 70 °C (x/h) 17
at 150 °C (x/h) 18
at 300 °C (x/h) 16
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 400 3N~
Nominal power (kW) 3,4
Energy consumption
at 70 °C (W) 520
at 150 °C (W) 1200
at 300 °C (W) 2340

 

1) To 98% of the set value

All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.