FD240 Full Specification

FD 240
Exterior dimensions
Width (mm) 1035
Height (incl. feet) (mm) 825
Depth (mm) 745
Plus door handle and connection (mm) 105
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 160
Exhaust duct (outer Ø mm) 52
Steam space volume (l) 308
Number of doors (ea.) 2
Interior dimensions
Width (mm) 800
Height (mm) 600
Depth (mm) 510
Interior volume (l) 240
Racks (number standard/max.) 2 / 7
Load per rack (kg) 30
Permitted total load (kg) 70
Weight (empty) (kg) 96
Temperature data
Temperature range approx. 5 °C above ambient temperature to (°C) 300
Temperature variation
at 70 °C (± K) 0,8
at 150 °C (± K) 2
at 300 °C (± K) 4,3
Temperature fluctuation at 70 °C (± K) 0,3
Warm-up time 1)
to 70 °C (min.) 11
to 150 °C (min.) 24
to 300 °C (min.) 50
Recovery time after doors were open for 30 sec. 1)
at 70 °C (min.) 2
at 150 °C (min.) 6
at 300 °C (min.) 13
Ventilation data
Ventilation 20
at 70 °C (x/h) 19
at 150 °C (x/h) 20
at 300 °C (x/h) 18
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 230
Nominal power (kW) 2,7
Energy consumption
at 70 °C (W) 370
at 150 °C (W) 850
at 300 °C (W) 1400

 

1) To 98% of the set value

All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.