FD115 Full Specification

FD 115
Exterior dimensions
Width (mm) 835
Height (incl. feet) (mm) 705
Depth (mm) 645
Plus door handle and connection (mm) 105
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 160
Exhaust duct (outer Ø mm) 52
Steam space volume (l) 158
Number of doors (ea.) 1
Interior dimensions
Width (mm) 600
Height (mm) 480
Depth (mm) 410
Interior volume (l) 115
Racks (number standard/max.) 2 / 6
Load per rack (kg) 20
Permitted total load (kg) 50
Weight (empty) (kg) 62
Temperature data
Temperature range approx. 5 °C above ambient temperature to (°C) 300
Temperature variation
at 70 °C (± K) 0,8
at 150 °C (± K) 1,8
at 300 °C (± K) 3,9
Temperature fluctuation (± K) 0,3
Warm-up time 1)
to 70 °C (min.) 7
to 150 °C (min.) 28
to 300 °C (min.) 49
Recovery time after doors were open for 30 sec. 1)
at 70 °C (min.) 2
at 150 °C (min.) 5
at 300 °C (min.) 12
Ventilation data
Ventilation
at 70 °C (x/h) 29
at 150 °C (x/h) 32
at 300 °C (x/h) 26
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 230
Nominal power (kW) 1,6
Energy consumption
at 70 °C (W) 230
at 150 °C (W) 544
at 300 °C (W) 1100

 

1) To 98% of the set value

All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.