ED 240 Full Specification

ED 240
Exterior dimensions
Width (mm) 1035
Height (incl. feet) (mm) 825
Depth (mm) 745
Plus door handle and connection (mm) 105
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 160
Exhaust duct (outer Ø mm) 52
Steam space volume (l) 283
Number of doors (ea.) 2
Interior dimensions
Width (mm) 800
Height (mm) 600
Depth (mm) 520
Interior volume (l) 240
Racks (number standard/max.) 2 / 7
Load per rack (kg) 30
Permitted total load (kg) 70
Weight (empty) (kg) 86
Temperature data
Temperature range approx. 5 °C above ambient temperature to (°C) 300
Temperature variation 1)
at 70 °C (± K) 1,5
at 150 °C (± K) 2,5
at 300 °C (± K) 5,0
Temperature fluctuation at 70 °C (± K) 0,3
Warm-up time 2)
to 70 °C (min.) 40
to 150 °C (min.) 48
to 250 °C (min.) 61
Recovery time after doors were open for 30 sec. 2)
at 70 °C (min.) 5
at 150 °C (min.) 13
at 300 °C (min.) 18
Ventilation data
Ventilation
at 70 °C (x/h) 11
at 150 °C (x/h) 10
at 300 °C (x/h) 9
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 230,1N~
Nominal power (kW) 2,7
Energy consumption
at 70 °C (W) 143
at 150 °C (W) 447
at 300 °C (W) 700

 

1) without a viewing window

2) To 98% of the set value

 

All technical data are specified for units with standard equipment at an ambient temperature of +25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.