ED 23 Full Specification

ED 23
Exterior dimensions
Width (mm) 435
Height (incl. feet) (mm) 495
Depth (mm) 520
Plus door handle, I-panel, connection (mm) 105
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 100
Exhaust duct (outer Ø mm) 52
Steam space volume (l) 36
Number of doors (ea.) 1
Interior dimensions
Width (mm) 222
Height (mm) 330
Depth (mm) 300
Interior volume (l) 20
Racks (number standard/max.) 2 / 3
Load per rack (kg) 12
Permitted total load (kg) 25
Weight (empty) (kg) 22
Temperature data
Temperature range approx. 5 °C above ambient temperature to (°C) 300
Temperature variation 1)
at 70 °C (± K) 1,5
at 150 °C (± K) 2,5
at 300 °C (± K) 3,8
Temperature fluctuation at 70 °C (± K) 0,3
Warm-up time 2)
to 70 °C (min.) 13
to 150 °C (min.) 24
to 250 °C (min.) 35
Recovery time after doors were open for 30 sec. 2)
at 70 °C (min.) 2,5
at 150 °C (min.) 5
at 300 °C (min.) 8
Ventilation data
Ventilation
at 70 °C (x/h) 10
at 150 °C (x/h) 13
at 300 °C (x/h) 17
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 230,1N~
Nominal power (kW) 0,8
Energy consumption
at 70 °C (W) 43
at 150 °C (W) 148
at 300 °C (W) 450

 

1) without a viewing window

2) To 98% of the set value
All technical data are specified for units with standard equipment at an ambient temperature of +25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.